Shop the 2in1 Soprano Titanium Ice Platinum Diode Laser. This ND:YAG equipment features three wavelengths (755, 808, 1064nm) for painless hair removing.
2-in-one Soprano Titanium Ice 4000W Triple Wavelength Diode & ND:YAG Laser Equipment
Realize Qualified-grade outcomes Along with the Soprano Titanium Ice Platinum, a strong 2-in-1 system combining three-wavelength diode laser technology for pain-free hair removing and also a Q-Switched ND:YAG laser for tattoo elimination and skin rejuvenation. Outfitted using a 4000W higher-electrical power motor and 5-amount adjustable cooling technological know-how, this CE-Qualified equipment supplies Risk-free, productive, and long-lasting benefits for all skin styles and human body locations.
Hair Removing: Triple wavelength (755nm, 808nm, 1064nm) for all skin tones
Pores and skin Correction: Q-Switched ND:YAG for tattoo elimination and carbon peeling
Ease and comfort: five-Degree adjustable cooling procedure for your painless working experience
Electricity: 4000W higher-Electricity density with German Diode Arrays
Crucial Features
three-Wavelength Diode Technology: Integrates 755nm (Alexandrite), 808nm (Pace), and 1064nm (YAG) wavelengths into a single applicator to focus on different hair depths and buildings simultaneously.
Twin-Function Technique: A true 2-in-one workstation featuring a committed Diode laser for permanent hair reduction plus a Q-Switched ND:YAG laser for pigmented lesion therapy and tattoo elimination.
Sophisticated five-Level Cooling: Functions the “Titanium Ice” five-degree adjustable cooling technology that keeps the sapphire idea at an ideal temperature, ensuring the procedure stays snug and pain-free.
High Output Functionality: Driven by a huge 4000W energy offer and German-imported Diode arrays, delivering as many as 2000mj Power density for rapid and efficient scientific outcomes.
Substantial Touchscreen Interface: Equipped that has a high-definition interactive Screen for specific Handle around Power degrees, pulse frequency, and cooling intensity across unique therapy modes.
Compatibility & Finest Use
Full Human body Software: Protected and productive to be used within the deal with (upper lip, chin), underarms, bikini line, arms, legs, back, and upper body.
All Pores and skin Types: The triple wavelength program is meant to get more info function properly on all pores and skin tones (Fitzpatrick scales I-VI) and hair colors, which includes great and light hair.
Skin Rejuvenation: Make use of the ND:YAG tackle with the black doll (carbon) tip for deep pore cleaning, pores and skin whitening, and anti-getting old treatment options.
Tattoo & Pigment Elimination: Focus on dim and coloured inks particularly using the Q-Change frequency for non-invasive removing of tattoos and freckles.
Set up Tips
Water Cooling Setup: This significant-ability laser requires distilled water for its cooling program; ensure the drinking water tank is crammed click here into the suggested degree just before powering to the device for The very first time.
Manage Link: Very carefully align the pins in the laser handles :Hair Removal Machine Together with the device ports and safe the locking system to be sure steady sign and cooling fluid transmission.
Voltage Verification: The machine supports 110V and 220V; make certain your electricity outlet matches the particular voltage options in check here the device to avoid electrical harm.
Parameter Calibration: For new customers, it is recommended to start treatments at the bottom Power settings and gradually increase dependant Laser Hair Removal on the shopper’s pores and skin sensitivity and comments.
Solution Specifications
Brand Identify emszero
Design Quantity Titanium 2-in-one (4000W)
Laser Wavelengths 755nm, 808nm, 1064nm (Diode) / 532nm, 1064nm, 1320nm (ND:YAG)
Electricity Output 4000W
Vitality Density As much as 2000mj (Adjustable)
Cooling Level five Stages Adjustable Sapphire Cooling
Certification CE
Voltage Compatibility AC 110V/220V, 50/60Hz
Packing Record
1 x Soprano Titanium two-in-1 Main Console (4000W)
one x 3-Wavelength Diode Laser Tackle
1 x Q-Swap ND:YAG Laser Cope with
3 x Specialised ND:YAG Recommendations (532nm, 1064nm, 1320nm)
1 x Ability Cable & Foot Pedal
one x User Handbook & Protective Goggles Set
Warnings & Basic safety Notes
Eye Security: Always don the presented laser-safety goggles during Procedure to stop long-lasting eye hurt from stray laser reflections.
In no way Operate Dry: Tend not to operate the equipment without having filling it with distilled water; jogging the laser with no performing cooling loop will cause instant interior hardware failure.
Contraindications: Will not use this unit on areas with open up wounds, active infections, or on people who are pregnant or have light-weight-sensitive clinical situations.
Cooling Routine maintenance: Change the distilled h2o every single three months to be sure The inner pump and laser arrays stay freed from mineral buildup and overheating.